A1706 Can not Boot when Press Power Button with Abnormal Standby Current
A1706 Can not Boot when Press Power Button Motherboard No. : 820-00239-A Malfunction : Can not Boot when Press Power Button with Abnormal Standby Current Troubleshooting: Remove the back cover, disconnect the battery and measure the current to see if the current changed. 1.If the current is not change, it means the problem is from the