El iPhone 6s no puede arrancar con una fuga de corriente de 50mA

El iPhone 6s no puede arrancar con una fuga de corriente de 50mA

Fenómeno del mal funcionamiento

Received an iPhone 6s with boot issue from customer.
Try to press the power key button to power on, the phone cannot be booted and check the DC power supply with 50mA current leakage.



Proceso de resolución de problemas

First, we should have some basic idea about the boot process main related chips and components. 

Just similar as iPhone series, like iPhone 7 and iPhone X. The boot process related with below main chips and components.

· Conector de batería: J2400

· Charging IC: U2300

· Power switch connector: J4700

· PMU: U2000

· 32.768KHz Crystal: Y2200

· 24MHz Crystal: Y0600

· CPU: U0600

 

And the block diagram as below, for detailed and HD block diagram you can download the Mapa de bits de Refox to have a check.

iPhone 6s Can Not Start Up

Then the second step, let’s take apart the phone and run the cosmetic inspection of motherboard.

Since the issue is can not start up with 50mA current leakage, based on repair experience.

There is a high chance the issue is caused by the lines between PMU and CPU, like the power supply rails and I2C control rails etc.

After checking, we found the R0900 is missing, which is just located in the I2C bus lines.

6s Can Not Start Up

iPhone 6s Can Not Start Up

Then resolder a resistor with the same specification and test, the phone can be booted normally.

Assmeble the phone and test again. All function works well, issue get resolved perfectly.

Resumen

The serious issue may caused by little components, do not afraid of the tough nut!

You can also learn more from Academia REWA, let’s make repair easier.