Samsung Galaxy S8 Plus no puede arrancar entonces con el símbolo de temperatura anormal

Defect Phenomenon Samsung Galaxy S8 Plus Cannot Boot   Troubleshooting Disassemble the phone, connected with DC power supply with 400mA current leakage. Keep powering for 10S, the touch with finger to feel the heat area, it located on the charging IC (IF PMIC).   Then we measure the chip related rail, find the main power

Samsung Galaxy S8 Plus no puede arrancar entonces con el símbolo de temperatura anormal Leer más »

A1706 No se puede activar la versión 2016

Motherboard No.:820-00239-08 Malfunction Phenomenon: Macbook A1706 2016 Version can not Be Turned On with abnormal standby status. Possible Reasons: The converting process of 5V to 20V was abnormal; The standby circuit or the chips related with standby circuit was abnormal; Troubleshooting: We connected with power and check the current when the voltage converting from 5V

A1706 No se puede activar la versión 2016 Leer más »

El iPhone XS no se puede encender con una corriente de 80 mA

Malfunction Phenomenon iPhone XS can not be turned on with the current 80 mA, and can not be connected with the computer.   Trouble Shooting We disassembled the phone and checked the motherboard, there wasn’t any obvious damaged area. We continued to separate the two layers of the motherboard and checked the pads. All the pads

El iPhone XS no se puede encender con una corriente de 80 mA Leer más »